New Products

  • b-63-mini-circuit-breaker-3p
    New

    MCB Solar DC Circuit Breaker 63A, 3Pole, 750V Max.

    0 out of 5

    APPLICATIONS:

    Standard Rated Current (A) Pole Voltage(V) Breaking Capacity(A)
    BS3871-1 IEC60898 1 to 40 50 to 63 1 240 6000
    2,3,4 415 6000
    IEC157-1 50 to 63 1 240 4000
    2,3,4 415 4000
    1 1 220/240 10000
    2,3,4 220/240 20000
    2,3,4 380/415 10000
    3 1 220/240 8000
    2,3,4 220/240 20000
    2,3,4 380/415 8000
    10 to 40 1 220/240 7000
    2,3,4 220/240 16000
    2,3,4 380/410 8000
    50 1 220/240 6000
    2,3,4 220/240 10000
    2,3,4 380/410 6000
    63 1 220/240 5000
    2,3,4 220/240 10000
    2,3,4 380/410 5000
    Standard Rated Current (A) Pole Voltage(V) Breaking Capacity(A)
    BS3871-1 IEC60898 1 to 40 1 240 4000
    2,3,4 415 4000
    IEC157-1 1 to 40 1 220/240 6000
    2,3,4 220/240 12000
    2,3,4 380/415 6000

    Setting temperature of protective characteristics at 40 ℃.
    Rated Voltage: 240V/415V\
    Rated Current: 1,3,5,6,10,16,20,25,32,40,50,63A.\
    Electrical Life: no than 6000 operations.
    Mechanical Life: (O-C) No less than 20000 operations.

    4,020.00
  • nc-100-2p-miniature-circuit-breaker
    New

    MCB Solar DC Circuit Breaker 125A, 2Pole, 06- 500V Max.

    0 out of 5
    Standard IEC/EN 60947-2
    Electrical features Rated current In A 63,80,100,125
    Poles 1P,2P,3P,4P
    Rated voltage Ue V 230/400
    Insulation voltage Ui V 500
    Rated frequency Hz 50/60
    Rated breaking capacity Ka 6~10
    Rated impulse withstand voltage(1.2/50)Uimp V 6000
    Dielectric test voltage at ind.Freq.for 1 min Kv 2.5
    Pollution degree 3
    Thermo-magnetic release characteristic 8-12In
    Mechanical
    features
    Electrical life 1500(In=63A,80A,100A)
    1000(In=125A)
    Mechanical life 8000(In=63A,80A,100A)
    7000(In=125A)
    Contact position indicator Yes
    Pollution degree IP20
    Standard IEC/EN 60947-2
    Reference temperature for
    setting of thermal element
    30
    Ambient temperature -5…+40(Special application please refer to P29 for temperature compensation correction)
    Combination
    with
    sccssorles
    (with daily average≦35℃)
    Storage temperation Terminal connection type -25..+70
    Cable/pin-type busbar
    Terminal size top/bottom for cable mm2 50
    AWG 18-1/0
    Terminal size top/bottom for busbar mm2 50
    AWG 18-1/0
    Tightening torque N*m 3.5
    In-Ibs. 3.1
    Mounting On DN rail EN 60715(35mm)by meas of fast clip device
    Connection
    Auxilary contact
    From top
    Auxilary contact Yes
    Rated current
    In (A)
    Temperature compensation coefficient under various operational temperature
    -10℃ 0℃ 10℃ 20℃ 30℃ 40℃ 50℃ 55℃ 60℃
    63 1.28 1.21 1.14 1.07 1.00 0.84 0.87 0.85 0.82
    80 1.22 1.16 1.11 1.05 1.00 0.95 0.91 0.88 0.86
    100 1.22 1.18 1.11 1.05 1.00 0.95 0.91 0.88 0.88
    125 1.22 1.16 1.11 1.05 1.00 0.95 0.91 0.88 0.86
    4,040.00
  • nc-100-2p-miniature-circuit-breaker
    New

    MCB Solar DC Circuit Breaker 100A, 2Pole, 06- 500V Max.

    0 out of 5
    Standard IEC/EN 60947-2
    Electrical features Rated current In A 63,80,100,125
    Poles 1P,2P,3P,4P
    Rated voltage Ue V 230/400
    Insulation voltage Ui V 500
    Rated frequency Hz 50/60
    Rated breaking capacity Ka 6~10
    Rated impulse withstand voltage(1.2/50)Uimp V 6000
    Dielectric test voltage at ind.Freq.for 1 min Kv 2.5
    Pollution degree 3
    Thermo-magnetic release characteristic 8-12In
    Mechanical
    features
    Electrical life 1500(In=63A,80A,100A)
    1000(In=125A)
    Mechanical life 8000(In=63A,80A,100A)
    7000(In=125A)
    Contact position indicator Yes
    Pollution degree IP20
    Standard IEC/EN 60947-2
    Reference temperature for
    setting of thermal element
    30
    Ambient temperature -5…+40(Special application please refer to P29 for temperature compensation correction)
    Combination
    with
    sccssorles
    (with daily average≦35℃)
    Storage temperation Terminal connection type -25..+70
    Cable/pin-type busbar
    Terminal size top/bottom for cable mm2 50
    AWG 18-1/0
    Terminal size top/bottom for busbar mm2 50
    AWG 18-1/0
    Tightening torque N*m 3.5
    In-Ibs. 3.1
    Mounting On DN rail EN 60715(35mm)by meas of fast clip device
    Connection
    Auxilary contact
    From top
    Auxilary contact Yes
    Rated current
    In (A)
    Temperature compensation coefficient under various operational temperature
    -10℃ 0℃ 10℃ 20℃ 30℃ 40℃ 50℃ 55℃ 60℃
    63 1.28 1.21 1.14 1.07 1.00 0.84 0.87 0.85 0.82
    80 1.22 1.16 1.11 1.05 1.00 0.95 0.91 0.88 0.86
    100 1.22 1.18 1.11 1.05 1.00 0.95 0.91 0.88 0.88
    125 1.22 1.16 1.11 1.05 1.00 0.95 0.91 0.88 0.86
    4,040.00
  • nc-100-2p-miniature-circuit-breaker
    New

    MCB Solar DC Circuit Breaker 80A, 2Pole, 06- 500V Max.

    0 out of 5
    Standard IEC/EN 60947-2
    Electrical features Rated current In A 63,80,100,125
    Poles 1P,2P,3P,4P
    Rated voltage Ue V 230/400
    Insulation voltage Ui V 500
    Rated frequency Hz 50/60
    Rated breaking capacity Ka 6~10
    Rated impulse withstand voltage(1.2/50)Uimp V 6000
    Dielectric test voltage at ind.Freq.for 1 min Kv 2.5
    Pollution degree 3
    Thermo-magnetic release characteristic 8-12In
    Mechanical
    features
    Electrical life 1500(In=63A,80A,100A)
    1000(In=125A)
    Mechanical life 8000(In=63A,80A,100A)
    7000(In=125A)
    Contact position indicator Yes
    Pollution degree IP20
    Standard IEC/EN 60947-2
    Reference temperature for
    setting of thermal element
    30
    Ambient temperature -5…+40(Special application please refer to P29 for temperature compensation correction)
    Combination
    with
    sccssorles
    (with daily average≦35℃)
    Storage temperation Terminal connection type -25..+70
    Cable/pin-type busbar
    Terminal size top/bottom for cable mm2 50
    AWG 18-1/0
    Terminal size top/bottom for busbar mm2 50
    AWG 18-1/0
    Tightening torque N*m 3.5
    In-Ibs. 3.1
    Mounting On DN rail EN 60715(35mm)by meas of fast clip device
    Connection
    Auxilary contact
    From top
    Auxilary contact Yes
    Rated current
    In (A)
    Temperature compensation coefficient under various operational temperature
    -10℃ 0℃ 10℃ 20℃ 30℃ 40℃ 50℃ 55℃ 60℃
    63 1.28 1.21 1.14 1.07 1.00 0.84 0.87 0.85 0.82
    80 1.22 1.16 1.11 1.05 1.00 0.95 0.91 0.88 0.86
    100 1.22 1.18 1.11 1.05 1.00 0.95 0.91 0.88 0.88
    125 1.22 1.16 1.11 1.05 1.00 0.95 0.91 0.88 0.86
    4,040.00
  • b-63-mini-circuit-breaker-2p
    New

    MCB Solar DC Circuit Breaker 63A, 2Pole, 06- 500V Max.

    0 out of 5

    APPLICATIONS:

    Standard Rated Current (A) Pole Voltage(V) Breaking Capacity(A)
    BS3871-1 IEC60898 1 to 40 50 to 63 1 240 6000
    2,3,4 415 6000
    IEC157-1 50 to 63 1 240 4000
    2,3,4 415 4000
    1 1 220/240 10000
    2,3,4 220/240 20000
    2,3,4 380/415 10000
    3 1 220/240 8000
    2,3,4 220/240 20000
    2,3,4 380/415 8000
    10 to 40 1 220/240 7000
    2,3,4 220/240 16000
    2,3,4 380/410 8000
    50 1 220/240 6000
    2,3,4 220/240 10000
    2,3,4 380/410 6000
    63 1 220/240 5000
    2,3,4 220/240 10000
    2,3,4 380/410 5000
    Standard Rated Current (A) Pole Voltage(V) Breaking Capacity(A)
    BS3871-1 IEC60898 1 to 40 1 240 4000
    2,3,4 415 4000
    IEC157-1 1 to 40 1 220/240 6000
    2,3,4 220/240 12000
    2,3,4 380/415 6000

    Setting temperature of protective characteristics at 40 ℃.
    Rated Voltage: 240V/415V\
    Rated Current: 1,3,5,6,10,16,20,25,32,40,50,63A.\
    Electrical Life: no than 6000 operations.
    Mechanical Life: (O-C) No less than 20000 operations.

    2,870.00
  • b-63-mini-circuit-breaker-2p
    New

    MCB Solar DC Circuit Breaker 50A, 2Pole, 06- 500V Max.

    0 out of 5
    Standard IEC/EN 60947-2
    Electrical features Rated current In A 63,80,100,125
    Poles 1P,2P,3P,4P
    Rated voltage Ue V 230/400
    Insulation voltage Ui V 500
    Rated frequency Hz 50/60
    Rated breaking capacity Ka 6~10
    Rated impulse withstand voltage(1.2/50)Uimp V 6000
    Dielectric test voltage at ind.Freq.for 1 min Kv 2.5
    Pollution degree 3
    Thermo-magnetic release characteristic 8-12In
    Mechanical
    features
    Electrical life 1500(In=63A,80A,100A)
    1000(In=125A)
    Mechanical life 8000(In=63A,80A,100A)
    7000(In=125A)
    Contact position indicator Yes
    Pollution degree IP20
    Standard IEC/EN 60947-2
    Reference temperature for
    setting of thermal element
    30
    Ambient temperature -5…+40(Special application please refer to P29 for temperature compensation correction)
    Combination
    with
    sccssorles
    (with daily average≦35℃)
    Storage temperation Terminal connection type -25..+70
    Cable/pin-type busbar
    Terminal size top/bottom for cable mm2 50
    AWG 18-1/0
    Terminal size top/bottom for busbar mm2 50
    AWG 18-1/0
    Tightening torque N*m 3.5
    In-Ibs. 3.1
    Mounting On DN rail EN 60715(35mm)by meas of fast clip device
    Connection
    Auxilary contact
    From top
    Auxilary contact Yes
    Rated current
    In (A)
    Temperature compensation coefficient under various operational temperature
    -10℃ 0℃ 10℃ 20℃ 30℃ 40℃ 50℃ 55℃ 60℃
    63 1.28 1.21 1.14 1.07 1.00 0.84 0.87 0.85 0.82
    80 1.22 1.16 1.11 1.05 1.00 0.95 0.91 0.88 0.86
    100 1.22 1.18 1.11 1.05 1.00 0.95 0.91 0.88 0.88
    125 1.22 1.16 1.11 1.05 1.00 0.95 0.91 0.88 0.86
    2,870.00
  • nc-100-2p-miniature-circuit-breaker
    New

    MCB Solar DC Circuit Breaker 40A, 2Pole, 06- 500V Max.

    0 out of 5

    APPLICATIONS:

    Standard Rated Current (A) Pole Voltage(V) Breaking Capacity(A)
    BS3871-1 IEC60898 1 to 40 50 to 63 1 240 6000
    2,3,4 415 6000
    IEC157-1 50 to 63 1 240 4000
    2,3,4 415 4000
    1 1 220/240 10000
    2,3,4 220/240 20000
    2,3,4 380/415 10000
    3 1 220/240 8000
    2,3,4 220/240 20000
    2,3,4 380/415 8000
    10 to 40 1 220/240 7000
    2,3,4 220/240 16000
    2,3,4 380/410 8000
    50 1 220/240 6000
    2,3,4 220/240 10000
    2,3,4 380/410 6000
    63 1 220/240 5000
    2,3,4 220/240 10000
    2,3,4 380/410 5000
    Standard Rated Current (A) Pole Voltage(V) Breaking Capacity(A)
    BS3871-1 IEC60898 1 to 40 1 240 4000
    2,3,4 415 4000
    IEC157-1 1 to 40 1 220/240 6000
    2,3,4 220/240 12000
    2,3,4 380/415 6000

    Setting temperature of protective characteristics at 40 ℃.
    Rated Voltage: 240V/415V\
    Rated Current: 1,3,5,6,10,16,20,25,32,40,50,63A.\
    Electrical Life: no than 6000 operations.
    Mechanical Life: (O-C) No less than 20000 operations.

    2,870.00
  • b-63-mini-circuit-breaker-2p
    New

    MCB Solar DC Circuit Breaker 32A, 2Pole, 06- 500V Max.

    0 out of 5

    APPLICATIONS:

    Standard Rated Current (A) Pole Voltage(V) Breaking Capacity(A)
    BS3871-1 IEC60898 1 to 40 50 to 63 1 240 6000
    2,3,4 415 6000
    IEC157-1 50 to 63 1 240 4000
    2,3,4 415 4000
    1 1 220/240 10000
    2,3,4 220/240 20000
    2,3,4 380/415 10000
    3 1 220/240 8000
    2,3,4 220/240 20000
    2,3,4 380/415 8000
    10 to 40 1 220/240 7000
    2,3,4 220/240 16000
    2,3,4 380/410 8000
    50 1 220/240 6000
    2,3,4 220/240 10000
    2,3,4 380/410 6000
    63 1 220/240 5000
    2,3,4 220/240 10000
    2,3,4 380/410 5000
    Standard Rated Current (A) Pole Voltage(V) Breaking Capacity(A)
    BS3871-1 IEC60898 1 to 40 1 240 4000
    2,3,4 415 4000
    IEC157-1 1 to 40 1 220/240 6000
    2,3,4 220/240 12000
    2,3,4 380/415 6000

    Setting temperature of protective characteristics at 40 ℃.
    Rated Voltage: 240V/415V\
    Rated Current: 1,3,5,6,10,16,20,25,32,40,50,63A.\
    Electrical Life: no than 6000 operations.
    Mechanical Life: (O-C) No less than 20000 operations.

    2,870.00

WHY SHOP WITH US?

RELIABILITY

Authentic & Reliable Products with High Quality Standards Guaranteed. No Fake Listings. No Hidden ChargesGet in Touch »

Our Services

We stand behind our goods and services and want you to be satisfied with them.Returns Policy »

Online Wire Transfer

Fast Deliveries All Over Pakistan.Learn More »